Pure sine wave inverters of Steca Xtender are regulated by a signal processor (DSP) are machines with lots of features, feature multifunction contacts (optional XTS ARM-02 for XTS series) that can be switched depending on many events as network availability, battery voltage, fault message, etc., but can also be programmed on a timer or activated at specific times.
Also through these contacts you can arm / disarm users or start a backup generator.
Another very important feature of these machines is the Smart Boost with which it is possible to increase the power of another source of alternating current or when special loads (inductive, asymmetric, with high inrush current).
Equipped with all the main guards to protect against deep discharge or disconnecting the battery for overvoltage, overtemperature and overload protection, short circuit protection and reverse polarity by internal fuse (except Steca Xtender XTH 3000).
Acoustic alarm at deep discharge or overheating.
In addition to 5 LEDs that indicate the states of Xtenders inverter operation they can be equipped with external display RCC-02 / RCC-03 required in the case of programming of the special functions.
The other option is the temperature sensor BTS-01, the processor to the state of the Steca battery BSP 500/1200.
Via the Steca X-Connect can be connected easily in three phase 3 XTH.
Also available are monitoring remotely via GSM and Ethernet.
You can also order special versions to 115 V @ 60 Hz (except XTH 8000-48) and sheet with protective enamel.
Dati tecnici
Modello |
XTS 900-12 |
XTS 1200-24 |
XTS 1400-48 |
Tensione di sistema [V] |
12 |
24 |
48 |
Potenza nominale [VA] |
500* |
650* |
750* |
Potenza 30 min. [VA] |
700* |
1000* |
1200* |
Potenza 5 sec. [VA] |
2300 |
2500 |
2800 |
Efficienza massima |
93% |
93% |
93% |
Tensione batteria [V]** |
9,5 … 17,0 |
19,0 … 34,0 |
38,0 … 68,0 |
Tensione di ingresso AC [V]** |
150 … 265 |
Corrente di carica [A]** |
0 … 35 |
0 … 25 |
0 … 12 |
Massima corrente in trasferimento [A] |
16 |
Potenza Smart-Boost 30 min. [VA] |
900 |
1200 |
1400 |
Ripartizione della potenza impostabile [A]** |
2 … 16 |
Tensione nominale uscita [V]** |
230 +/- 2 % |
Frequenza nominale uscita [Hz]** |
50 +/- 0,05% |
Temperatura ambiente [°C] |
-20 ° … +55 ° |
Grado di protezione |
IP54 |
Modello |
XTM 1500-12 |
XTM 2000-12 |
XTM 2400-24 |
XTM 2600-48 |
XTM 3500-24 |
XTM 4000-48 |
Tensione di sistema [V] |
12 |
12 |
24 |
48 |
24 |
48 |
Potenza nominale [VA] |
1500 |
2000 |
2000 |
2000 |
3000 |
3500 |
Potenza 30 min. [VA] |
1500 |
2000 |
2400 |
2600 |
3500 |
4000 |
Potenza 5 sec. [VA] |
3400 |
4800 |
6000 |
6500 |
9000 |
10500 |
Efficienza massima |
93% |
93% |
94% |
96% |
94% |
96% |
Tensione batteria [V]** |
9,5 … 17,0 |
9,5 … 17,0 |
19,0 … 34,0 |
38,0 … 68,0 |
19,0 … 34,0 |
38,0 … 68,0 |
Tensione di ingresso AC [V]** |
150 … 265 |
Corrente di carica [A]** |
0 … 70 |
0 … 100 |
0 … 55 |
0 … 30 |
0 … 90 |
0 … 50 |
Massima corrente in trasferimento [A] |
50 |
Potenza Smart-Boost 30 min. [VA] |
1500 |
2000 |
2400 |
2600 |
3500 |
4000 |
Ripartizione della potenza impostabile [A]** |
1 … 50 |
Tensione nominale uscita [V]** |
230 +/- 2 % |
Frequenza nominale uscita [Hz]** |
50 +/- 0,05% |
Temperatura ambiente [°C] |
-20 ° … +55 ° |
Grado di protezione |
IP20 |
Modello |
XTH 3000-12 |
XTH 5000-24 |
XTH 6000-48 |
XTH 8000-48 |
Tensione di sistema [V] |
12 |
24 |
48 |
48 |
Potenza nominale [VA] |
2500 |
4500 |
5000 |
7000 |
Potenza 30 min. [VA] |
3000 |
5000 |
6000 |
8000 |
Potenza 5 sec. [VA] |
7500 |
12000 |
15000 |
21000 |
Efficienza massima |
93% |
94% |
96% |
96% |
Tensione batteria [V]** |
9,5 … 17,0 |
19,0 … 34,0 |
38,0 … 68,0 |
38,0 … 68,0 |
Tensione di ingresso AC [V]** |
150 … 265 |
Corrente di carica [A]** |
0 … 160 |
0 … 140 |
0 … 100 |
0 … 120 |
Massima corrente in trasferimento [A] |
50 |
Potenza Smart-Boost 30 min. [VA] |
3000 |
5000 |
6000 |
8000 |
Ripartizione della potenza impostabile [A]** |
1 … 50 |
Tensione nominale uscita [V]** |
230 +/- 2 % |
Frequenza nominale uscita [Hz]** |
50 +/- 0,05% |
Temperatura ambiente [°C] |
-20 ° … +55 ° |
Grado di protezione |
IP20 |
* potenza maggiore tramite ECF-01
** programmabile tramite RCC-02 / RCC-03